FUJITSU MCM3064AP User Manual
Page 128

Host Interface
4-58
C156-E227-01EN
Table 4.65 Removable Block Access Capabilities Page default value
Bit
Byte
7
6
5
4
3
2
1
0
2
0
1
000000b
3
1
0
000b
001b
4-11
00h
4.6.5.6 Timer & Protect Page
Table 4.66 Timer & Protect Page
Bit
Byte
7
6
5
4
3
2
1
0
0
PS
0
Page Code (1Ch)
1
Page Length (06h)
2
Reserved
3
Reserved
Inactivity Time Multiplier
4
Reserved
DISP
SWPP
5-7
Reserved
Inactivity Time Multiplier defines the minimum period beginning from when an
access command ends until entry to standby mode. For the relationship between
the specified value and period, see Table 4.67, "Inactivity Time Multiplier values."
When a value in a range of 1h to 9h is specified, Ah is assumed and the command
responds with Recovered Error.