beautypg.com

Frymaster 8196321 User Manual

Page 7

background image

H50/52/55

1-3

Gas Control Box Components

Item

Part #

Component

1 826-2264

Interface

Board

2

807-3366†

Ignition Module, Dual-spark Full-vat

*

807-3365†

Ignition Module, Single-spark Dual-vat

*

807-1006

Ignition Module for Pre-August 2000 units

3 807-3484

Connector,

Rajah

4

807-0833

Relay, DPDT 5A 12VDC Latch

*

807-0834

Relay, SPDT 15A 12VDC Basket Lift (See Note 2 below)

5

826-2024

Cable, 21-inch Ignition (comes with Rajah connector)

6

806-6085SP

Flame Sensor wire assembly

* 826-1721

Ignition

Cable

(2 ignition cables, 2 rajah connectors)

* 807-1200

Ignition

Wires,

27-inch (used with 807-1006)

* 807-1878

Ignition

Wires,

19-inch

(used with 807-1006)

*

806-3660

Sound Device, High Output

* 826-2458

Speaker,

McDonald’s

* 810-3141

SMT

Sound

Device

* Not illustrated.


† For dual-vat units, use 807-3365 Single-Spark Ignition Module (see NOTE 1).

NOTE 1: Dual-vat units use two 807-3365 Single-Spark Ignition Modules. Full-vat units use one
807-3366 Dual-spark ignition module. Also, in full-vat units, only one latch relay is used, located
in the lower right socket.

NOTE 2: Basket lift relays are present only on units equipped with basket lifts.