Gsms – Frymaster 8196321 User Manual
Page 51
GSMS
10-3
Control Box and Related Components
ITEM
PART #
COMPONENT
1
807-1396
Relay, 24VDC SPDT (Basket Lift Relay – GSMS and GBC units only)
2
Transformer
807-0800
120VAC/24VAC, 50/60 Hz, 50VA
807-0680
208-240VAC/24VAC, 50/60 Hz, 43VA
3
807-3366
Module, Honeywell Dual-Spark FV Ignition (See NOTE below.)
4
807-0670
Relay, 24V DPDT (Heat Relay – all units)
5
106-0676SP
Cable, Ignition (used with Item 3 – also requires Item 8)
6
807-1709
Cable, Ignition (used with 807-1006 Ignition Modules)
7
806-5316SP
Wire Assembly, 20-inch High Temperature (Flame Sensor Wire)
8
807-3484
Connector, RAJAH (two required for each 807-3366 Ignition Module)
NOTE: Control box assemblies on units manufactured before October 2000 were built with
two single-spark ignition modules (P/N 807-1006). If an 807-1006 module fails, the control
box may be retrofitted with one dual-spark ignition module (P/N 807-3366) and two RAJAH
connectors (P/N 807-3484). If this option is chosen, the earlier style ignition cables (P/N 807-
1709) must also be replaced with the new ignition cables (P/N 106-0676SP).