beautypg.com

Fault codes – Fisher & Paykel DD60 User Manual

Page 38

background image

36

Fault codes

Fault codes

Possible causes

What to do

U1

Fill fault due to...

...water supply not
being turned on.

OR

...spray arm not being
fitted correctly.

Check if there is water in the

DishDrawer and follow the relevant
steps below.

If there is no water in the DishDrawer:

1

Turn on the water supply to the

DishDrawer.

2

Plug the DishDrawer back in or turn

it on at the power supply.

If there is water in the DishDrawer:

1

Plug the DishDrawer back in or turn

it on at the power supply.

2

Press the

button and wait for 30

seconds.

3

Press the

/

button. The

DishDrawer will automatically drain
(approx. 2 minutes). You may need to
repeat steps 2 and 3 again.

4

When the DishDrawer is empty,

check that the spray arm is correctly
fitted and can rotate freely. See ‘User
maintenance instructions’.

U4

Fault in the other
drawer preventing the
use of this drawer.

Check other drawer, attend to fault code
on that drawer.