4. INSTALLATION

33

8. Position the two cable clamps and fasten

them in place. If used, push the cable
cover over the cable and screw it in place.

9. Route the cable to the instrument being

careful not to tear the cable jacket when
passing it though the bulkhead(s) and
other parts of the boat. To reduce electrical
interference, separate the sensor cable
from other electrical wiring and "noise"
sources. Coil any excess cable and secure
it in place with zip-ties to prevent damage.

4.6

Optional Water
Temperature/Speed
Sensor

Water temperature/speed sensor ST-02MSB
and ST-02PSB, which are designed for thru-
hull mounting, are optionally available. Install
them as shown below.

Mounting considerations

Choose a suitable mounting location consid-
ering the following:

• Choose a place free from vibration.
• Choose a mid-boat flat position. The sensor

does not have to be installed perfectly per-
pendicular. The sensor must not be dam-
aged in dry-docking operation.

• Choose a place apart from equipment gen-

erating heat.

• Choose a place in the forward direction

viewing from the drain hole, to allow for cir-
culation of cooling water.

1. Dry-dock the boat.
2. Make a hole of approx. 51 mm diameter in

the mounting location.

3. Unfasten locknut and remove the sensor

section.

4. Apply high-grade sealant to the flange of

the sensor.

5. Pass the sensor casing through the hole.
6. Face the notch on the sensor toward boat's

bow and tighten the flange.

7. Set the sensor section to the sensor casing

and tighten the locknut.

8. Launch the boat and check for water

leakage around the sensor.

Water temperature/speed sensor

ST-02MSB, ST-02PSB

4.7

Optional Water
Temperature Sensor

Transom mount water temperature
sensor T-02MTB

• Fix the cable at a convenient location on the

transom with the cable clamp.

• When the cable is led through the transom

board, make a hole of approx. 17 mm in
diameter to pass the connector. After
passing the cable, seal the hole with a
sealing compound.

How to mount transom mount water

temperature sensor T-02MTB

Locknut

Face "notch"
toward bow.

Flange Nut

Coat with
silicone sealant.

Brim

φ

77

51

123

D 50 cm

D

5x20

Flush with hull bottom.

>