beautypg.com

FRIGIDAIRE 137153400A User Manual

Page 8

background image

8

The following are specifi c requirements for proper and safe
electrical installation of your dryer. Failure to follow these
instructions can create electrical shock and/or a fi re hazard.

Electrical installation

Front Console Dimensions

Rear Console Dimensions

- ELECTRICAL SHOCK HAZARD -

This appliance MUST be properly grounded. Electrical

shock can result if the dryer is not properly grounded. Fol-
low the instructions in this manual for proper grounding.

Do not use an extension cord with this dryer. Some ex-

tension cords are not designed to withstand the amounts
of electrical current this dryer utilizes and can melt, creat-
ing electrical shock and/or fi re hazard. Locate the dryer
within reach of the receptacle for the length power cord
to be purchased, allowing some slack in the cord. Refer
to the pre-installation requirements in this manual for the
proper power cord to be purchased.

- ELECTRICAL SHOCK HAZARD -

A U.L.-approved strain relief must be installed onto pow-

er cord. If the strain relief is not attached, the cord can be
pulled out of the dryer and can be cut by any movement
of the cord, resulting in electrical shock.

Do not use an aluminum wired receptacle with a copper

wired power cord and plug (or vice versa). A chemical
reaction occurs between copper and aluminum and can
cause electrical shorts. The proper wiring and receptacle
is a copper wired power cord with a copper wired recep-
tacle.

Dryers operating on 208 volt power supply will have

longer drying times than dryers operating on 240 volt power
supply.

2 9/16”

(6.5 cm)

4 3/8”

(11 cm)

4 3/8”

(11 cm)

3 3/4”

(9.5 cm)

3 3/4”

(9.5 cm)

27” (68.6 cm)

27” (68.6 cm)

2 9/16”

(6.5 cm)

1”

(2.5 cm)

1”

(2.5 cm)

13 1/2”

(34.4 cm)

13 1/2”

(34.4 cm)

3 3/4”

(9.5 cm)

3 3/4”

(9.5 cm)

36”

(91.5 cm)

36”

(91.5 cm)

43 5/8”

(111 cm)

34 5/8”

(87.9 cm)

electrical supply on rear of unit,

power cord length on gas unit

approximately 59” (150 cm)

to center of

rear vent

to center of

rear vent

gas supply pipe on

rear of gas unit

47 1/2” (120.7 cm)

to clear open door

47 1/2” (120.7 cm)

to clear open door

optional vent

knockout

optional vent

knockout

gas supply pipe on

rear of gas unit

center line

height for

rear vent

center line

height for

rear vent

under-counter

installation height

electrical supply on rear of unit,

power cord length on gas unit

approximately 59” (150 cm)