6 gas inputs – Frymaster SM80 User Manual
Page 22

DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-9
3.6 Gas Inputs
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Part Number and Quantity/Color are listed in the
table below:
MODEL NOMINAL
HEAT
INPUT- Qn
(kW)
GAS
TYPE
ORIFICE SIZE
(MM)
ORIFICE
PART NO.
ORIFICE
QTY/ COLOR
SM 80 GM
37.5
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
5/BLUE
5/BLUE
5/RED
SM 60 GM
37.5
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
5/BLUE
5/BLUE
5/RED
SR 52 GM
SM 50 GM
30
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
4/BLUE
4/BLUE
4/RED
SM 35 GM
SR 38G
SR 42G
26
G20
G25
G31
2.40
2.40
1.51
810-2060/*810-3101
810-2060/*810-3101
810-2059/*810-3102
3/BLUE
3/BLUE
3/RED
SM 20 GM
15
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
2/BLUE
2/BLUE
2/RED
*Use these orifices on SR42 fryers built after 4/07.
A. Adjustments for different gases are as follows:
GAS PRESSURE AT
REGULATOR
MODEL*
ORIFICE
SIZE (MM)
GAS TYPE
MBAR INCH
W.C.
BURNER
MARKING
PILOT
MARKING
SM 80GM
2,40
2,40
1,51
2,40(1)
G20
G25
G31
G25(1)
10,0
15,0
27,0
10,0(1)
4,0
6,0
10,8
4,0(1)
Blue
Blue
Red
Blue
26N
26N
16LP
26N
SM 60GM
2,40
2,40
1,51
G20
G25
G31
12,0
17,5
22,0
4,8
7,0
8,8
Blue
Blue
Red
26N
26N
16LP
*SR prefix- Super Runner Series
*SM prefix- Super Marathon Series
*GM suffix- gas millivolt system with no electrical supply connections required
(1) The Netherlands (NL) only.