3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent
on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel
and housing with hot tap water, then dry with a clean cloth.
Wrap the motor and
wires with plastic wrap
or a plastic bag.
BLOWER HOUSING
BLOWER WHEEL
4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor
assembly and blower housing. Reinstall the blower assembly in the fryer.
5. Reinstall the blower shield or shield assembly.
6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.
7. After the burners have been lit for at least 90 seconds, observe the flames through the burner
viewing ports located on each side of the combustion air blower.
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the
applicable table on page 3-7 and the burners display a bright orange-red glow. If a blue flame is ob-
served, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.