beautypg.com

Preparation of input channels – Fostex FM-3 User Manual

Page 7

background image

Preparation of input channels

(1)

Connect a microphone or line level source to each

of the [INPUT] connectors (1 through 3).

(2)

When you connect a microphone, set the input

select switch to “MIC”. When you connect a line

level source, set the input select switch to “LINE”.

(3)

When you connect a microphone, set the

microphone power supply switch appropriately.

When you connect a condenser microphone that

requires +48 V phantom power, set the switch to “P48”.

When you connect a condenser microphone that

requires T-12 power (A-B 12 V) such as Sennheiser

416T, set the switch to “P48”. When you connect a

dynamic microphone, set the switch to “DM”.

(1)

Connect an external audio device such as a

recorder to the [MAIN OUT] connectors (L and R).

(2)

Set the output level switch appropriately depending

on the device connected.

You can select from +4 dBu, 0 dBu, -20 dBu and -60

dBu.

(3)

To connect a -10 dBV unbalanced line level device,

use the [TAPE OUT] connector (stereo mini jack).

The nominal output level of this connector is fixed

to -10 dBV.

You can turn on the unit by setting the [POWER] switch

on the front panel to “INT” (upper position) or “EXT” (lower

position). When you operate the unit on internal battery

power, set the switch to “INT”.

When you operate the unit on external power, set it to

“EXT”. When you turn on the unit for the first time, the

display shows the stereo VU meters as shown below.

When you operate the unit on (internal on external) bat-

tery power, confirm that the battery power is sufficient by

checking the battery indicator on the meter display.

You can check the power voltage of the battery power

source from the system status display (see page 20).

Battery indicator

: If you do not need T12 (A-B 12 V) power

supply capability, you can disable this capability from

the input status display. By default, it is enabled. See

page 16 for details.

Preparation of output channels

Preparation of metering

(1)

Select stereo or mono metering.

When the unit is shipped, the display is set to stereo

VU and peak metering.

You can change it to L or R channel mono metering (see

page 15 for details).

(2)

Adjust the display brightness if required.

When the unit is shipped, the display brightness is set

to “Level 3”.

You can change it to the optimum brightness according

to the circumstance. See page 14 for details.

: Using the meter status display, you can

disable or enable the peak meter function, select

the VU meter reference level, and select the “OVR”

indicator lighting level (see page 19 for details).

Stereo metering

Mono metering (L)

7