Fairchild CAM/CCD-4KCL.TDI User Manual
Page 19

CBR
This command allows you to change the Baud Rate. You will not see anything
on your monitor.
Here is a table of stored rates in the camera…Value Function
1 9600
2 19200
3 38400 (Default)
4 57600
5 115200
If you can’t resist changing the baud rate, select the appropriate single digit
number and hit enter.
LED
This command allows you to change the color. When selecting the option you
need to, enter the appropriate single digit number and hit enter. Your screen will
be blank during this command. You can input one of the following:
Value Function
0
Amber
1 Green
2 Red
3 Off
SAP
Store in Flash both correction memories, all registers and DAC values.
Value Function
Store all parameters
0 Default factory calibrate
1 User
2 User
The power on values will be the last saved from SAP (X).
RAP
Load from flash to camera. Recall all parameters
Value Function
0 Default factory calibration
1 User
2 User
SBS
Value Function
Set bit shift
0 10 bit
1 9 bit
2 8 bit
Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 19 of 30