beautypg.com

Parts supplied, Cavity preparation, Important – Fisher & Paykel DD24ST User Manual

Page 3

background image

PARTS SUPPLIED

Clamp (1)

Wire clip (1)

Phillips

5⁄8

” (16 mm)

screws (7)

1

½

” (38 mm)

bottom

fixing screws

& metal

washers (2)

Drain hose

support (1)

Moisture protection

tape (1)

(to prevent moisture

damage)

Cavity bracket

kit (1)

(supplied only with

Prefinished flat door

and Integrated models)

Drain hose

joiner (1)

Rubber

washer for

inlet hose (1)

Edge protector (1)

(if services hole

partition is metal)

If the Drain hose(s) supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose(s) by 11’ 10” (3.6m). The kit is available from the nearest Fisher & Paykel
Authorized Service Agent, or Toll free 1.888.936.7872 or www.fisherpaykel.com.

4

5

Important!

Be sure the edges of the services hole are smooth or covered. If the services hole is through a metal
partition the hole must be protected with the Edge protector supplied to prevent damage to the
power cord or hoses.

These marks indicate formed bracket screw locations.

Note: To align drawer front to adjacent cabinetry, the product to countertop clearance can
be increased to 1⁄8”

(

3 mm).

Preferred position. If adequate clearance, services hole can be higher.

If hole is higher, ensure drain hose(s) are routed straight into the waste connection.

Water Connection

Recommended HOT (Maximum 140°F/60°C).

Supplied hose to suit 3/8” (9 mm) male compression fitting.

*

CAVITY PREPARATION

Water Pressure

Max

Min

Water softener models

1 MPa (145 psi)

0.1 MPa (14.5 psi)

Other models

1 MPa (145 psi)

0.03 MPa (4.3 psi)

Drains will need to be separated to satisfy kosher requirements. We suggest you confirm
acceptability with your local rabbi in respect to kosher installations.

2” x 4”

Note: Se

rvices can be locat

ed

either side of DishDra

wer®.

Important!

Adjacent cabinetry must not
extend above cavity base

110-120 VAC
max. 15 A

min.

7

7⁄8

(200 mm)

3⁄8”

(10 mm)

max.

17

11⁄16

(450 mm)

Water supply

max. ø

1

½

” (38 mm)

Moisture

protection

tape must

be applied.

If no side partition,

use a brace for

securing.

*

*

Left hand

side

Right hand

side

Side mounting

bracket kit

(A and B) (2)
OPTIONAL

Top mounting

brackets (2)
OPTIONAL

Max. distance of
hoses and cord from
chassis edge

Left hand

side

Right hand

side

Drain hose

78 ½

(2000 mm)

70 ½

(1800 mm)

Inlet hose

64 ¾

(1650 mm)

49”

(1250 mm)

Power cord

(excl. plug)

29 ½

(750 mm)

27 ½

(700 mm)

(2,1) -1- 599754C DD24S TALL installA2 USCA.indd 15/4/09 2:34:15 PM