Removing a fortiswitch-5003a board – Fortinet 5003A User Manual
Page 18
FortiSwitch-5003A System Guide
18
01-30000-77803-20080917
Removing a FortiSwitch-5003A board
Hardware installation
10
Once the board is inserted correctly, fully tighten the retention screws to lock the
FortiSwitch-5003A board into position in the chassis slot.
Removing a FortiSwitch-5003A board
The following procedure describes how to correctly use the FortiSwitch-5003A
mounting components described in
“FortiSwitch-5003A mounting components” on
to remove a FortiSwitch-5003A board from an ATCA chassis slot.
FortiSwitch-5003A boards are hot swappable. The procedure for removing
a FortiSwitch-5003A board from a chassis slot is the same whether or not the
chassis is powered on.
To remove a FortiSwitch-5003A board from a chassis slot
To complete this procedure, you need:
• An ATCA chassis with a FortiSwitch-5003A board installed
• An electrostatic discharge (ESD) preventive wrist strap with connection cord
1
Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on the chassis or frame.
2
Disconnect all cables from the FortiSwitch-5003A board, including all network
cables and the console cable.
Tighten
Retention
Screw
!
Caution: Do not carry the FortiSwitch-5003A board by holding the handles or retention
screws. When inserting or removing the FortiSwitch-5003A board from a chassis slot,
handle the board by the front panel. The handles are not designed for carrying the board. If
the handles become bent or damaged the FortiSwitch-5003A board may not align correctly
in the chassis slot.
!
Caution: FortiSwitch-5003A boards must be protected from static discharge and physical
shock. Only handle or work with FortiSwitch-5003A boards at a static-free workstation.
Always wear a grounded electrostatic discharge (ESD) preventive wrist strap when
handling FortiSwitch-5003A boards.