beautypg.com

Room ventilation, 1 connection to liquid gas – Foster Gas Cooker Hobs 9606801 User Manual

Page 12

background image

30

ENGLISH

INSTALLER INSTRUCTIONS

IMPORTANT: Always place the gasket between the hob fitting and the connection

pipe.

• If using a stainless steel flexible pipe, it must be installed so that it does not

come in contact with any part of the cabinet, but passes through an unoccupied

area where its entire length can be inspected. Maximum extension of the flexible

pipe must be less than 2 metres.

• The gas fitting is the type with a 1/2” gas ISO R7 tapered thread.

After connecting the appliance to the gas supply network always verify fittings

seal using a soapy solution.

VERIFYING THE SEAL USING NAKED FLAMES IS ABSOLUTELY PROHIBITED.

The cooker hob is tested for methane gas G20 (2H) at a pressure of

20 mbar. For supplying with other types of gas, see the Adapting to the different

types of gas table

[

Page 31

]

8.1 Connection to liquid gas

Use a pressure regulator and realise connection on cylinder in compliance with the

prescriptions established by the current Standards.
Ensure the supply pressure respects the values indicated in the table

Adapting to different types of gasses

[

Page 31

]. In this case also, connection

must be carried out with copper rigid pipe or with stainless steel flexible pipe with

continuous wall.

9. Room ventilation

IMPORTANT: The appliance can only be installed in rooms that are permanently

ventilated, as required by standards in force.