Table 5.11 Data format of SMART Summary Error Log
Byte
Item
00
Version of this function
01
Pointer for the latest "Error Log Data Structure"
02 to 31
Reserved
32
Device Control register value
33
Features register value
34
Sector Count register value
35
Sector Number register value
36
Cylinder Low register value
37
Cylinder High register value
38
Drive/Head register value
39
Command register value
3A to 3D
Command data
structure
Elapsed time after the power-on
sequence (unit: ms)
3E
Reserved
3F
Error register value
40
Sector Count register value
41
Sector Number register value
42
Cylinder Low register value
43
Cylinder High register value
44
Drive/Head register value
45
Status register value
46 to 58
Vendor unique
59
State
5A
5B
Error log data
structure
Error data
structure
Power-on time (unit: h)
5C to 1C3
Error log data
structure 2 to
Error log data
structure 5
Format of each error log data structure is same as those of
bytes 02 to 5B.
1C4, 1C5
Number of unrecoverable errors that have occurred.
1C6 to 1FE
Reserved
1FF
Check sum