beautypg.com

Remote menu operation, Specifications – Hitachi KP-E500 User Manual

Page 19

background image

External key switch connections for remote operation

Remote menu operation

1.Color system

NTSC

2.Pickup element

1/2-inch progressive scan frame

interline CCD( with on-chip microlenses )

Total pixels 680(H)

×

500(V)

Effective pixels

658(H)

×

489(V)

Scanning area 6.58(H)

×

4.89(V)mm

Sell size 10.0(H)

×

10.0(V)μm

3.Scanning system

2:1 interlace

4.Scanning frequency

Hor. 15.734kHz

Ver. 59.94Hz

5.Sync system

internal

6. Video signal output

KP-DE500:VBS1.0Vp-p/75Ω

KP-E500:VS1.0Vp-p/75Ω

7. Signal processing

Digital processing ( input 10 bits )

8. S/N

( Y signal )

More than 50dB

(AGC,enhancer and gamma OFF)

9. Resolution

( Y signal at center ) Hor. :480 lines

Ver.

350 lines

10.Minimum illumination

KP-DE500

0.009 lx ( Color, F1.4, AGC ON, SENS UP OFF, 50IRE )

0.0005 lx( Monochrome, F1.4, AGC ON, SENS UP OFF, 50IRE )
0.00015lx(Color 64 time accumulation, F1.4, AGC ON, 50IRE)
0.000008lx

(Monochrome 64 time accumulation, F1.4, AGC ON, 50IRE)

KP-E500

0.0003 lx

(Monochrome, F1.4, AGC ON, SENS UP OFF, 50IRE )

0.000005

lx

(Monochrome 64 time accumulation, F1.4, AGC ON, 50IRE)

11. Sensitivity setting

AGC OFF/ON(Factory setting is1/60)

Manual Gain Adjustable at AGC OFF

Limit Gain Adjustable at AGC ON

12. Electronic shutter speeds

Selectable in 7 steps & AES
( Factory setting is 1/60 )
1/60,1/100,1/125,1/250,1/500,1/1000,1/2000
AES:From 1/60 second to 1/2000 second

13.

Integration multiple [SENS UP] setting

Automatic or Manual (fixed) ( Factory setting is OFF )

Automatic : 2,4,6,8,10,12,16,32,64 times

Manual

:

2,4,6,8,10,12,16,32,64,88,128 times

14. Backlight compensation

ON/OFFswitchable

Sensing area:selectable from 9 areas

15.Auto-iris lens outputs

Video signal
Input type lens

Luminance signal
1.0Vp-p/high impedance
Power supply 12V DC 40mA

Iris control voltage input
(galvanometer)

Coupling coil impedance
Damper:1150Ω±10%
Drive:190Ω±10%

Specifications

32

33

An optional remote plug is available to enable operating
the camera mode and set buttons by remote control.
Confirm the plug is properly wired as indicated in the
figure and connect it to the rear panel Remote connector.
Do not connect anything to the unused Pins.

1

5

3

8

2

9

10

12

11

6

7

4

Remote plug(option)

UP

DOWN

SET

Pin Signal Abbrev.

Remarks

1

Not connected

N.C.

Do not connect

2

Serial

data

input

Tx

Connect to RS-232C
data terminal

3

Serial

data

output

Rx

Connect to RS-232C
data terminal

4

Up key

UP

Key switch connection

5

Down key

DOWN

Key switch connection

6

Not connected

N.C.

Do not connect

7

Not connected

N.C.

Do not connect

8

Set key

SET

Key switch connection

9

Not connected

N.C.

Do not connect

10

GND GND

Connect

to

RS-232C

ground

11

Not connected

N.C.

Do not connect

12

Not connected

N.C.

Do not connect


Remote operation with RS-232C
Signals 2, 3 and 10 can be used for control by personal
computer. Consult dealer for retailed information.

Keep the distance between the remote plug and
external key switches to less than about 2 meters.
Disconnect the remote plug from the camera Remote
connector when not using the key switches.

NOTE
Be sure to switch off the camera power before
connecting or disconnecting the remote plug.

This manual is related to the following products: