Read before installation – haier AU282AHERA User Manual
Page 11
Tools/Materials
Use
Notes
Gas leak detector
Detection of gas leaks
The ones for HFC type refrigerant
may be used.
Vacuum Pump
Vacuum drying
May be used if a reverse flow check
adaptor is attached.
Refrigerant Recovery
Equipment
Recovery of refrigerant
May be used if designed for use with
R410A.
Flare Tool
Flare machining of piping
Chages have been made in the flare
machining dimension.Refer to the
next page.
Tools/Materials
Use
Notes
Vacuum Pump with a
Check valve
Vacuum drying
Bender
Bending pipes
Pipe Cutter
Cutting pipes
Torque Wrench
Tightening flare nuts
Only 12.70 (1/2'') and 15.88(5/8'')
have a larger flare machining
dimension.
Welder and Nitrogen
Cylinder
Welding pipes
Refrigerant Charging
Meter
Refrigerant charging
Vacuum Gauze
Checking vacuum degree
Tools/Materials
Use
Notes
Charging Cylinder
Refrigerant Charging
Must not be used with R410-type units.
Maximum Operation Pressure
Applicable Refrigerants
3.4MPa
R22, R407C
4.15MPa
R410A
* Use pipes that meet the local standards.
Read Before Installation
9
2. Tools and materials that may be used with R410 with some restrictions
3. Tools and materials that are used with R22 or R407C that can also be used with
R410A
4. Tool and materials that must not used with R410A
Tools for R410A must be handled with special care; keep moisture and dust from
entering the cycle.
Piping Materials