beautypg.com

Service settings, cont – Hague Quality Water Intl WATERMAX 60 SERIES User Manual

Page 17

background image

WaterMax 60 Series Owner’s Manual

11/10/2008

17

Service Settings, Cont.

Display

Meaning

Possible Values

Comments

72–96 Hour
Regeneration

No

A way to force regeneration at
regularly-scheduled intervals

No (or Yes, for iron)

See

72–96 Hour

Regeneration that follows.
Displays only when in
Modes 2 or 3

Distiller/RO No

Indicates

if

a distiller or reverse

osmosis appliance is plumbed to use
filtered water from the appliance

No (or Yes if a distiller or
reverse osmosis appliance
is used)

Displays only when in
Mode 2

Backwash 1

01.0

Number of minutes the first backwash
cycle lasts

00.0 to 99.9

Set to the nearest tenth of
a minute

Brine/Rinse 30.0

Number of minutes the first brine and
slow rinse cycle lasts

00.0 to 99.9

Set to the nearest tenth of
a minute

Backwash 2

05.0

Number of minutes the second
backwash cycle lasts

00.0 to 99.9

Set to the nearest tenth of
a minute

Salt per
Regen lbs.

06.2

Amount of salt set to be used in each
regeneration to achieve the capacity
setting

00.0 to 99.9 lb (kg)

Set to the nearest tenth

Turbine Pulses
Normal

Used by qualified personnel for
diagnostic purposes

Normal
Test Mode

Regenerate
Tonight

Yes

Sets the appliance to regenerate
tonight

No or Yes

If set to Yes, it will force a
regeneration at the next
set regeneration time
(such as 02:00 AM). After
the regeneration, the value
will be set to No.
Displays only when in
Modes 1 or 2