beautypg.com

Heat & Glo Fireplace Heat & Glo Fireplace AT-GRAND User Manual

Page 9

background image

6

A vertical vent termination system installed on this

model will include one (1) length of 3-inch flexible vent

pipe for the combustion air, one (1) pipe-to-cap

adaptor, and one (1) SLK-991DA or SLK-980D Vertical

termination Cap.
NOTE: The damper of the masonry chimney may

need to be removed to allow installation of the flexible-

vent pipe.
This fireplace has been altered to accommodate an

insert and should be inspected by a qualified person

prior to re-use as a conventional fireplace.
NOTE: The above label, located in the instruction

package, must be affixed to the existing fireplace prior

to installation of Model AT-GRAND.
For zero clearance, factory built woodburning

fireplaces, the use of kit LINK-ZC-ADP, in place of the

standard square flashing, will allow you to mount the

adaptor and cap on metal pipe. Additionally, the use of

kit FLASH-DAMP will seal off the damper opening

when terminating the inlet air vent pipe just above the

damper. These two kits are recommended for zero

clearance, factory built woodburning fireplaces.
Connecting the Vent Pipe
Install the 3-inch flexible vent pipes down through the

chimney. Attach and secure the bottom ends of the

flex pipes to the starting collars on the unit with 3

sheetmetal screws on each collar. Slide the gas insert

into place, and position any excess flex vent pipe back

up into the chimney.
Attach the pipe-to-cap adaptor to the termination cap

and the top of the flexible vent pipe and set the cap in

place at the top of the chimney. See Figures 3, 4 & 5.
TO AVOID DOWNDRAFTS AND/OR COLD AIR

PROBLEMS, IT IS RECOMMENDED TO SEAL

OFF THE AREA BETWEEN THE TERMINATION

CAP AND THE TOP OF THE SOLID-FUEL

CHIMNEY OPENING INTO WHICH THE VENT

CAP HAS BEEN INSTALLED.

When using the LINK-DV4-30 vent system, it is required

to seal around the flexible vent pipes in the damper

area. See Figure 3. Use fiberglass insulation or other

suitable non-combustible material.

VENT SYSTEM APPROVALS

AT-GRAND

LINK-DV30

LINK-DV4-30

TABLE 1

CAUTION