beautypg.com

Installation – Hampton Direct H25-NG1 User Manual

Page 21

background image

Hampton

®

H25-1 Direct Vent Freestanding Gas Stove

21

Pipe Length (max. 18")

Part (6-5/8" Dia)

(4" Dia.)

Decorative

Wall Trim

Part #640-545/P

Horizontal
Terminal
Part# 640-530/P

Wall Thimble

Part # 946-202

(required for

combustible walls)

Vinyl Siding
Standoff (Optional)
Part #946-205

Adapter

Part #946-219/P

(required)

INSTALLATION

RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES

MINIMUM HORIZONTAL TERMINATION INSTALLATIONS

You will require the following components with your new Hampton

®

Rear Vent Direct Vent Free-

standing Gas Stove. Please review your product to make sure you have everything you need. In
the event that you are missing any part, contact your dealer. Decorative brass
or chrome trim kits are available from Simpson Dura-Vent for their
wall thimbles, as well as a square wall thimble cover.

Planning Your venting Installation

See the "Exterior Vent Terminatal Locations"
section for requirements.
The H25 is approved
for a minimum horizontal termination with the
FPI Riser Vent Kit. See the diagram for minimum
and maximum pipe lengths.

When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. Determine the
minimum clearance to combustibles from the
rear of the unit to the wall. It is also important to
note the wall thickness. Before cutting the vent
hole through the wall ensure that ALL vent and
termination clearances (see the "Exterior Vent
Terminal locations" section) will be met.

*If this is an outside corner, the minimum distance
between the vent and the outside corner is 6"
(15cm). See "F" on the diagram in the "Exterior
Vent Terminal Locations" section.

NOTE: Ensure compliance with the outside
vent terminal location before cutting hole as
both dimensions must be met.

Note: These are the minimum pieces re-

quired. Other parts may be required
for your particular installation.

Minimum components for a Horizontal Installation:
640-944

Horizontal Termination Kit which includes:

1

6-5/8" Dia. x 18" Black Pipe

1

4" Dia. x 18" Aluminum Vent

1 946-202

Wall Penetration Heat Shield (Wall Thimble) (2 pcs)

1

640-530/P

Riser

Vent

Terminal

1

640-545/P

Decorative

Wall

Trim

(Black)

1

948-128

Tube

Mill-Pac

Screws

946-219/P 1 Adapter

Optional Components:
946-204

45

o

Elbow - 6-5/8" Black pipe

and 4" Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent

Terminal

946-208/P Vent

Guard

940

Square Wall Thimble Cover*

981

Snorkel

Termination

(36")*

982

Snorkel

Termination

(14")*

942

Wall

Penetration

Heat

Shield*

* Simpson Dura-Vent components

This manual is related to the following products: