beautypg.com

Electrical – Wolf 15 Inch Transitional Induction Cooktop Installation Instructions User Manual

Page 5

background image

wolfappliance.com

|

5

WARNING

The complete appliance must be properly grounded at
all times when electrical power is applied.

Do not ground appliance with the neutral (white) house
supply wire. A separate ground wire must be utilized.

If aluminum house supply wiring is utilized, splice the
appliance copper wire to the aluminum house wiring
using special connectors design and agency certified
for joining copper and aluminum. Follow the connector
manufacturer's recommended procedure carefully.
Improper connection can result in a fire hazard.

SPECIFICATIONS


Induction cooktop.


Electric cooktop.

RATING PLATE

RATING PLATE

Electrical

Installation must comply with all applicable electrical codes.

Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.

When multiple cooktops are installed side by side, each unit
must have its own separate recommended electrical circuit.

ELECTRICAL REQUIREMENTS

INDUCTION

Electrical Supply

3-wire, 240/208 VAC, 60 Hz

Conduit

flexible 4'

(1.2 m)

ELECTRIC

Electrical Supply

3-wire, 240 VAC, 60 Hz

Conduit

flexible 4'

(1.2 m)

SERVICE

15" Induction / Electric

20 amp dedicated circuit

24" Induction

30 amp dedicated circuit

30" Induction / Electric

40 amp dedicated circuit

36" Induction / Electric

50 amp dedicated circuit