Ilford SFX 200 Black and White Negative Film (35mm Roll Film, 36 Exposures) User Manual
Page 4
Page 4 of 6
Nov 2018
SFX 200
Technical Information
35mm and Roll Film
ILFORD developer Dilution
Meter setting (EI)
200/24 400/27 800/30
Spiral tank, deep tank, dip and dunk machines (min/20
°
C/68
°
F)
ILFOTEC DD-X
1+4
10 14
−
ILFOSOL 3
1+9
6
8½
--
1+14
9
13½
−
ILFOTEC HC
1+15
5 7 10½
1+31
9
13 19
ILFOTEC LC29
1+9
5
7
10½
1+19
9
13
19
1+29
11
−
−
ID-11
stock
10
14
18
1+1
17
−
−
MICROPHEN
stock
8½
10½
14½
1+1
15½
19
−
PERCEPTOL
stock
14½
−
−
1+1
20
−
_
Non-ILFORD Developers (min/20
°
C/68
°
F)
Developer
Dilution
Meter setting (EI)
200/24 400/27 800/30
Kodak D-76
stock
10
12½
16½
1+1
14½
−
−
Kodak HC-110
A
5 7 10½
B 9
13 19
Kodak T-Max
1+4
8½ 10½ 12½
Tetenal Ultrafin
1 + 10
10
13
−
Kodak Xtol
stock
7
11
−
Dip and dunk machines (min/24°C/75°F)
ILFOTEC DD
1+4
8½
11½
14
Kodak T-Max RS
stock
6
7
9
Kodak Xtol
stock
7
9
11½
ILFOLAB FP40, roller transport and short leader machines (sec/26°C/79°F)
ILFOTEC RT RAPID
1+1+2
54
65
88
1+1+5
65
90
120
Note.
Development times may need adjusting to suit individual processing systems and working practices. If an
established system is producing good results, adjust the recommended development times until the desired
contrast level is obtained. Development times in other manufacturers’ developers are included for your
convenience and are only a general guide. Other manufacturers can and do change their product
specifications from time to time, and the development times may change as a result.