Ilford Delta 3200 Black and White Negative Film (120 Roll Film) User Manual
Page 4

Page 4 of 7
Nov 2018
DELTA 3200 PROFESSIONAL
Technical Information
35mm and Roll Film - 24°C/75°F
ILFORD developer Dilution
Meter setting (EI)
400/27 800/30 1600/33 3200/36 6400/39
12500/42
Spiral tank, deep tank, dip and dunk machines (min/24
°
C/75
°
F)
ILFOTEC DD-X*
1+4
−
5 6
7 9 12
ILFOSOL 3
1+9
5½
7 8
9
15
½
−
1+14
7
8
10
11
19
−
ILFOTEC HC
1+15
−
−
−
5½
8½
−
ILFOTEC HC
1+31
5
6
7
10½
−
−
ILFOTEC LC29
1+9
−
−
−
5½
8½
−
1+19
5
6
7
10½
−
−
ID-11
stock
6
7
8
9
11
13½
MICROPHEN*
stock
−
5
6
7
9½ 13½
PERCEPTOL
stock
9½
10½
12
15½
−
−
Non-ILFORD Developers (min/24
°
C/75
°
F)
Rodinal
1+25
−
−
5½
7½
15
−
Kodak D-76
stock
6
7
8
9
11
13½
Kodak HC-110
A
−
−
−
5½
8½
−
B
5
6
7
10½
−
−
Kodak T-Max
1+4
−
5½ 6½ 7½ 9½ 13
Kodak Xtol
stock
−
5½
6
7 9 11
* = Recommended developers
Dip and dunk machines (min/24°C/75°F)
ILFOTEC DD
1+4
8
8½
9½
10½
13½
19
Kodak T-Max RS
stock
4
4½ 5 6½
8½
10½
Kodak Xtol
stock
8
9 10½
13½
17½
23
ILFOLAB FP40, roller transport and short leader machines (sec/26°C/79°F)
ILFOTEC RT RAPID
1+1+2
54
65
73
84
104
−
1+1+5
95
108
120
153
176
−
NOTE
When using meter settings of EI 12500/42 and above, it is important to make test exposures first to ensure the
results will be suitable for the intended purpose. A guide to development times for meter settings EI 12500/42
is given in the development time tables. For exposures at EI 25000/45, use the guide in the below table.
Meter setting EI 25000/45 manual processing
ILFORD Developer Dilution
20°C/68°F
min
24°C/75°F
min
ILFOTEC DD-X
1+4
25
17
MICROPHEN STOCK 22
17½