beautypg.com

页 12, Technical data, Protection function – Godox VING V860IIN TTL Li-Ion Flash Kit for Cameras User Manual

Page 13: Over-temperature protection, Other protections

background image

Technical Data

- 49 -

- 50 -

V860IIN

Nikon DSLR cameras (i-TTL autoflash)

60 (m ISO 100)

190 (feet ISO 100)

20 to 200mm (14mm with wide panel)

• Auto zoom (Flash coverage set automatically

to match the lens focal length and image size)

• Manual zoom

• Swinging/tilting flash head (bounce flash): 0 to 360°

horizontally and -7° to 90° vertically

1/300 to 1/20000 seconds

i-TTL autoflash and manual flash

Manual. FEB: ±3 stops in 1/3 stop increments

(Manual FEC and FEB can be combined.)

High-speed sync (up to 1/8000 seconds),

first-curtain sync, and second-curtain sync

Provided (up to 90 times, 100Hz)

Master, Slave, Off

3 (A, B, and C)

Indoors: 12 to 15 m / 39.4 to 49.2 ft.

Outdoors: 8 to 10 m / 26.2 to 32.8 ft.

Master unit reception angle: ±40° horizontally,

±30° vertically

100m

4 (1, 2, 3, and 4)

32 (1~32)

Two red indicators blink

Fired with camera’s depth-of-field preview button

Center: 0.6~10m / 2.0~32.8 feet

Periphery: 0.6~5m / 2.0~16.4 feet

11.1V/2000mAh Li-ion polymer battery

<1.5 seconds. Red LED indicator will light up when

the flash is ready.

Approx. 650

Power off automatically after approx. 90 seconds

of idle operation. (60 minutes if set as slave)

Hotshoe, 2.5mm sync line, Wireless control port

5600±200k

64*76*190 mm

430g

540g

Model

• Type

Compatible Cameras

Guide No.

(1/1 output @ 200mm)

Flash Coverage

Flash Duration

• Exposure Control

Exposure control system

Flash exposure

compensation (FEC)

Sync mode

Multi flash

• Wireless Flash (Optic transmission and 2.4G transmission)

Wireless flash function

Controllable slave groups

Transmission

Optic

range

(approx.)

2.4G

Channels

Optic

2.4G

Slave-ready indicator

Modeling flash

• Auto Focus Assist Beam

Effective range (approx.)

• Power Supply

Power source

Recycle time

Full power flashes

Power saving

• Sync Triggering Mode

• Color Temperature

• Dimensions

W x H x D

Weight without battery

Weight with battery

Protection Function

1. Over-Temperature Protection

To avoid overheating and deteriorating the flash head, do not fire

more than 30 continuous flashes in fast succession at 1/1 full

power. After 30 continuous flashes, allow a rest time of at least 10

minutes.

If you fire more than 30 continuous flashes and then fire more

flashes in short intervals, the inner over-temperature protection

function may be activated and make the recycling time over 10

seconds. If this occurs, allow a rest time of about 10 minutes, and

the flash unit will then return to normal.

When the over-temperature protection is started,

is shown on

the LCD display.

Number of flashes that will activate over-temperature

protection:

Meaning

A failure occurs on the recycling system so that the

flash cannot fire.

Please restart the flash unit. If the problem still exists,

please send this product to a maintenance center.

The system gets excessive heat. Please allow a rest

time of 10 minutes.

The voltage on two outlets of the flash tube is too high.

Please send this product to a maintenance center.

There are some errors occurred during the upgrading

process. Please using the correct firmware upgrade

method.

Prompts on LCD Panel

E1

E2

E3

E9

2. Other Protections

The system provides real-time protection to secure the device and

your safety. The following lists prompts for your reference:

Number of flashes that will activate over-temperature

protection in high-speed sync triggering mode:

Power Output Level

1/1

1/2 +0.7

1/2 +0.3

1/2

1/4(+0.3,+0.7)

1/8(+0.3,+0.7)

1/16(+0.3,+0.7)

1/32(+0.3,+0.7)

1/64(+0.3,+0.7)

1/128(+0.3,+0.7)

Number of Flashes

30

40

50

60

100

200

300

500

1000

Power Output

1/1

1/2(+0.3,+0.7);

1/4(+0.3,+0.7)

1/8(+0.3,+0.7);

1/16(+0.3,+0.7)

1/32(+0.3,+0.7);

1/64(+0.3,+0.7);

1/128(+0.3,+0.7);

Times

15

20

30

40

50