beautypg.com

Firmware upgrade, Technical data, Other protections – Godox TT350F Mini Thinklite TTL Flash for Cameras User Manual

Page 12

background image

Number of flashes that will activate over-temperature protection in
high-speed sync triggering mode:

Power Output Level

1/1

1/2 +0.7

1/2 +0.3

1/2

1/4(+0.3,+0.7)

1/8(+0.3,+0.7)

1/16(+0.3,+0.7)

1/32(+0.3,+0.7)

1/64(+0.3,+0.7)

1/128(+0.3,+0.7)

Number of Flashes

30

40

50

60

100

200

300

500

1000

Power Output

1/1

1/2(+0.3,+0.7);

1/4(+0.3,+0.7)

1/8(+0.3,+0.7);

1/16(+0.3,+0.7)

Times

15

20

30

40

Meaning

A failure occurs on the recycling system so that the
flash cannot fire.
Please restart the flash unit. If the problem still exists,
please send this product to a maintenance center.
The voltage on two outlets of the flash tube is too high.
Please send this product to a maintenance center.
There are some errors occurred during the upgrading
process. Please using the correct firmware upgrade
method.

Prompts on LCD Panel

E1

E3

E9

2. Other Protections

The system provides real-time protection to secure the device and
your safety. The following lists prompts for your reference:

Firmware Upgrade

This flash supports firmware upgrade through the USB port. Update
information will be released on our official website.

USB connection line is not included in this product. The USB
port is a standard Micro USB socket. Common USB
connection line is applicable.

Checking the version: Press the Button and the turn
the flash on. Then, the firmware update version (e.g. Version
1.0 will read U-1.0) will be displayed on the LCD panel.

Technical Data

TT350F

FUJI cameras

(Please reference to compatible camera models)

36 (m ISO 100)

24 to 105mm (135 format)

• Auto zoom (Flash coverage set automatically

to match the lens focal length and image size)

• Manual zoom

• Swinging/tilting flash head (bounce flash): 0 to 270°

horizontally and -7° to 90° vertically

1/350 to 1/20000 seconds

TTL autoflash and manual flash

Manual. FEB: ±3 stops in 1/3 stop increments

(Manual FEC can be combined.)

High-speed sync (up to 1/8000 seconds),

first-curtain sync, and second-curtain sync

Provided (up to 90 times, 90Hz)

Master, Slave, Off

3 (A, B and C)

30m

16 (1~16)

Model

• Type

Compatible Cameras

Guide No.

(1/1 output @ 105mm)

Flash Coverage

Flash Duration (t0.1)

• Exposure Control

Exposure control system

Flash exposure

compensation (FEC)

Sync mode

Multi flash

• Wireless Flash (2.4G radio

transmission)

Wireless flash function

Controllable slave groups

Transmission range

(approx.)

Channels

Ni-MH batteries (recommended) or 2*LR6 alkaline batteries

Approx. 0.1-2.2 seconds (eneloop Ni-MH batteries
of Panasonic). Red LED indicator will light up when
the flash is ready.

• Auto Focus Assist Beam

Effective range (approx.)

• Power Supply

AA batteries

Recycle time

Full power flashes

Power saving

• Sync Triggering Mode

• Dimensions

W x H x D

Weight without battery

Center: 0.6~4m

Periphery: 0.6~2.5m

Approx. 210 (2500mA Ni-MH batteries)

Power off automatically after approx. 90 seconds

of idle operation. (60 minutes if set as slave)

Hotshoe, optic triggering

140*62*38 mm

210g

Number of flashes that will activate over-temperature protection:

- 45 -

- 46 -