Page 17

background image

C

.

Fn

Ver 0.5

99

CH

GR

ID

1. Disturbed by the 2.4G signal in outer environment (e.g. wireless base station, 2.4G wifi

router, Bluetooth, etc.)

→ To adjust the channel CH setting on the flash trigger (add 10+ channels) and use the channel

which is not disturbed. Or turn off the other 2.4G equipment in working.

2. Please make sure that whether the flash has finished its recycle or caught up with the

continuous shooting speed or not(the flash ready indicator is lighten) and the flash is not

under the state of over-heat protection or other abnormal situation.

→ Please downgrade the flash power output. If the flash is in TTL mode, please try to change it to

M mode(a preflash is needed in TTL mode).

3. Whether the distance between the flash trigger and the flash is too close or not

→ Please turn on the “close distance wireless mode” on the flash trigger (<0.5m):

→ X1 series: Press and hold the flash button, then turn on the machine until the indicator

light flashes twice.

X2, Xpro series: Set C.Fn-DIST to 0-30m.

4. Whether the flash trigger and the receiver end equipment are in the low battery states or not

→ Please replace the battery(the flash trigger is recommended to use 1.5V disposable alkaline battery).

The Reason & Solution of Not Triggering in Godox 2.4G Wireless

1. Press the < > button to enter C.Fn and turn the select dial to choose the custom
setting functions.
2. Press the SET button and turn the select dial to set the parameters.
3. After finishing all the settings, press the SET button to confirm and press the < >
button to exit.

Custom Function Signs
MODE

PHOTOC

WL

GR
CH
ID
STBY

Functions
Flash mode

S1/S2 Light
controlled flash

Wireless setting

Group setting
Channel setting
ID setting
Auto power off

Settings
M
TTL
OFF
S1
S2
ON
OFF
A/B/C/D/E
1~32
OFF/01~99
OFF
30min
60min
90min

Settings & Descriptions
Manual flash
Auto flash
Off
S1 Secondary Optic Triggering
S2 Secondary Optic Triggering with Anti-preflash
Wireless on
Wireless off
Choose any letters from A/B/C/D/E
Choose any figure from 1 to 32
Choose any figure from 01 to 99 or OFF
Off
The flash will automatically shut down when
unattended operation for a long time
(more than 30/60/90 minutes).

When the light’s system crashes or cannot be operated, insert a needle into the reset hole to
forced shutdown the device.

ID Setting

Enter C.Fn menu and turn the select dial to choose ID.
Press the SET button and turn the select dial to choose
ID from OFF and 01 to 99. Then, short press the SET
button to exit from ID setting.

Note: this can only be used when the main unit has this
function.

C.Fn: Setting Custom Functions

Forced Shutdown Function

- 29 -

- 30 -

When the continuous flashes fires up to 50 times in fast succession at 1/1 full power, an Over-
Temperature Protection symbol appears on the display to remind the user that the flash unit is
overheated. It is recommended to temporarily stop the macro flash.

Over-Temperature Protection

Long press menu button and modeling lamp button at the same time to realize the function

of settings reset function.

Reset Function