3.0 - 1B 4X and Control Characters
Sending the following command bytes to the CTOV box will cause the VPI output to assert the appropriate remote function line. The
VPI print/plot line will be placed low (raster mode) before the remote function line is asserted:
1B 41
remote clear
1B 42
remote line terminate
1B 43
remote end of transmission
1B 44
remote form feed
1B 45
remote reset
1B 50 ZZ asserts repeating remote line terminates from ZZ = 01 hex to
FF hex
NOTE:
These commands must be sent when the CtoV box is in print mode (section 2). The commands will be ignored and interpreted as
raster data if they are sent at any other time.
The CtoV box also obeys standard control characters that must be sent when the CtoV box is in print mode:
04
end of transmission
0A
line feed
0C
form feed
0D
(carriage return - this byte is ignored)
4.0 - Interface Timing
Centronics Timing
Parameter Minimum Maximum
strobe width (A)
strobe to busy (B)
busy width (C)
acknowledge width (D)
init width (E)
200nS
125nS
900nS
550nS
200nS
-
150nS
note 1
note 2
no max