iSys V36 User Manual
Page 30

Data rates
The following table shows the required input data from the host to the V36 to
support the different plot speeds.
Plot Speed
Minimum Data Rate
0.125 inches/sec
88.8 kB/sec
0.25 inches/sec
177.6 kB/sec
0.50 inches/sec
355.2 kB/sec
0.75 inches/sec
532.8 kB/sec
1.0 inches/sec
710.4 kB/sec
maximum
1065.6 kB/sec
T H E O R Y O F
O P E R A T I O N
Print mode
When the host asserts the PRINT mode signal, the plotter can generate ASCII
characters.
ASCII characters are produced as plot patterns on a matrix through the use
of a Character Generator ROM. When one complete print line of ASCII-
coded data is received, the data is converted into plot patterns. Each character
line is executed over 40 plot scans.
The 96 ASCII characters are coded as shown in Table E.1. Control codes
are shown in Table E.2. (see Appendix E).