“Temperature Updates”
Once internal registers are configured, it is possible to read temperatures on the 338-
VP and 390.

“Serial Numbers Read Back”
Both modules SMT338-VP and SMT390 have a unique silicon serial number. This
function allows to read-then back and therefore identify the boards.

“Capturing data”
This command captures data from both channels, one after the other (not
simultaneously). Data are then stored into two separate files into the directory where
the application has been started. Files are called ChannelA.txt and ChannelB.txt

Pegasus application (to be done).
The SMT8090_374 is also provided with a Pegasus application (Pegasus folder),
which shows the user the dynamic performance of the system.