beautypg.com

Typical installation of direct vent water heater, Alternate piping arrangement, On/off – Paloma PH-28c Direct Vent User Manual

Page 23

background image

23

Typical Installation of Direct Vent Water Heater

Discharge

Line

(To Suitable Drain)

To Hot Water

Faucet(s)

Relief
Valve

Union

Drain Valve

6" (15 cm) Air Gap

Manual Gas

Appliance

Shut-off

(supplied)

Sediment

Trap

Manual

Gas Supply Line

Shut-off

Valve

Union

Cap

Cold Water

Supply

Shut-off

Valve

Check

Valve

°F

PRIORITY

POWER

ON/OFF

Remote
Control

Power

Supply

Cord

Water Filter

Drain Valve

Drain

Hose

(To Suitable Drain)

NOTICE: The National Fuel Gas Code (NFGC) and B149 mandates a manual gas shut-off valve:
See NFGC/B149 for complete instructions. Local codes or plumbing authority requirements may
vary from the instructions or figures provided and take precedent over these instructions.

Vacuum Relief Valve

(Not Supplied)

If required, install per local codes

and valve manufacturer’s

instructions.

Water Inlet

Water Outlet

Drain

Pressure Relief Valve

Hot Water Service Valve

Cold Water Service

Valve

Alternate Piping Arrangement

90° Elbow

Outside Wall

Vent Adapter

1/4” Per Foot Downward
Pitch towards termination

Air Intake Tee

Outside Wall

Outside
Faceplate

Inside Faceplate

4”/7” Concentric

Pipe

Air Intake
Opening

Vent
Termination
with screen

Air Intake Pipe

Vent Outlet

Pipe

Silicone

Silicone

This manual is related to the following products: