INSTALLATION (cont.)

Plugging in the Unit

1. Check the prongs and surface of the power cord plug for dust/dirt. If dust and/

or dirt are present, wipe off with a clean, dry cloth.

2. Check the power cord, plug and prongs for damage or excess play. If any

damage or excess play is found, contact your MovinCool dealer for

replacement.

WARNING:

• If the power cord or plug is damaged, replacement must be

performed by qualified electrical personnel.

• Do not connect or disconnect the power cord or attempt to operate

buttons with wet hands. This could result in electrical shock.

• Because of potential safety hazards under a certain condition, we

strongly recommend against the use of an extension cord. However,

if you still elect to use an extension cord, it is absolutely necessary

that it is a UL listed, 3-wire grounding type appliance extension cord,

having a 3-blade and a 3-slot receptacle that plugs into the

appliance. The marked rating of the extension cord should be the

following rating or equivalent.

3. Check the power supply outlet rating and fuse size to match with table below.

CAUTION: The power source should be a dedicated single outlet

circuit with UL recognized short-circuit and ground fault protective

breaker. Do not share the power supply outlet with any other

instrument or equipment. The minimum power supply rating and

the recommended fuse size are listed above.

Note:

• Make sure the power supply outlet is free of dirt, dust, oil, water, or any other

foreign matter.

• The Climate Pro 18 is equipped with UL recognized LCDI cord and NEMA plug

configuration (5-20). The appropriate outlet must be used for this plug type.

Model

Rating of Extenstion Cord

Climate Pro 18

120 V, 20 A

Model

Minimum Power Supply Rating

Recommended Fuse Size

Climate Pro 18

115 V, 1 Phase, 60 Hz, 20 A

20 A maximum