Lynx Studio E44 User Manual
Page 48
48
Volume up, CTRL + SHIFT + M for Mute, etc. If you encounter a problem, simply have the
Volume Control Settings app learn a new key sequence.
8.6 Connector Pinouts
The E22 and E44 cards have two external ports for connecting cables to audio equipment, as
well as internal clock connections. The pinouts below are presented as a convenience should
one wish to use custom cables, rather than the Lynx branded options.
8.6.1 Audio Port
The Audio Port is a female 25-pin D-connector with the following connections:
Please note: for the E22 card, only In 1+2 and Out 1+2 are active. The other pins are not
utilized.
Pin
Signal
Pin
Signal
1
OUT 4 Hot
14
OUT 4 Cold
2
OUT 4 Gnd
15
IN 4 Hot
3
IN 4 Cold
16
IN 4 Gnd
4
OUT 3 Hot
17
OUT 3 Cold
5
OUT 3 Gnd
18
IN 3 Hot
6
IN 3 Cold
19
IN 3 Gnd
7
OUT 2 Hot
20
OUT 2 Cold
8
OUT 2 Gnd
21
IN 2 Hot
9
IN 2 Cold
22
IN 2 Gnd
10
OUT 1 Hot
23
OUT 1 Cold
11
OUT 1 Gnd
24
IN 1 Hot
12
IN 1 Cold
25
IN 1 Gnd
13
none