14 factory setting – ifm electronic JN2301 User Manual
Page 20

Inclination sensor JN
20
14 Factory setting
Index
Type
Value
Delivery
0x1000
u8
TxPGN0 active
1: is sent cyclically
0x2000
u8
Device address
25
0x2001
u16
Baud rate
250 Kbits
0x2040
u8
Flag for quadrant correction
1: corresponds to "± 180°”
0x2041
u8
Flag for heating
1: corresponds to "heating on"
0x2042
u8
Index teach value of the X/Y/Z axes
2: corresponds to "absolute measurement"
0x2043
u8
FIR filter step
2: corresponds to "FIR lowpass 5Hz"
0x2044
u8
Angle calculation
0: corresponds to "perpendicular"
0x2045
u8
CAN 120 Ω terminating resistor
1: corresponds to "activated"
0x2046
u8
Set zero point of the X/Y axes
2: corresponds to "absolute measurement"