Setup, Control panel – Formax FD 340 User Manual
Page 6
SETUP
1. Install upper and lower fold plates in position. Be sure
the plates are set fi rmly on the locating pins (Fig 1a
& 1b). Slide the fold plate in until it meets the fi rst
locating pin then push down to lock it in position
(Fig. 2).
2. Make sure the power switch is in the “OFF” position.
3. Plug the power cord into the power inlet and the wall
outlet.
No. NAME
FUNCTION
1
Power Indicator
Lights up when power is on.
2
Start Button
Press to run the machine. Will not operate if a red fault light is on.
3
Stop Button
Press to stop the machine.
4
Test Button
Test folds two documents.
5
Fault Indicator Lights
Stops the operation and indicates the problem area. Turn off the light by closing
cover, and/or placing paper on the in-feed tray. Press the “Reset” button to turn off
the “Fault detect” light.
6
Batch Counting Button Select the batch counting function.
7
“-“ and “+” buttons
Select the number of documents to be folded.
8
Reset Button
Resets the fault detect circuit and the counter.
CAUTION: when a fault happens and light is lit, only press the button one time. If
you press it a second time, you will reset the counter.
9
Counter Display
Shows the number of documents processed. When power is turned on it displays
“F-01”.
Fig. 1a
Locating Pins
Locating Pins
Fig. 1b
Locating Pins
Locating Pins
Locating Pins
Locating Pins
CONTROL PANEL
2
Fig. 2
Upper Fold Plate Pins
Lower Fold Plate Pins
1
7
2 3 4
5
9
8
6