The memory image of the K-bus resides in the lower memory region (D000 to D0400). This region separates in input
and output region. Since firmware version ≥ B3 it is possible to shift the I/O regions. In this way the process image
can be adapted to the needed space. To each I/O-region the is a control block. Each block consists of 8 byte for
diagnosis purpose. These regions can be shifted, too. The following table shows the structure of the interface. The
offset addresses are default values.

Legacy PLC interface (inputs)

Offset

default

0x1F8 [2]

diagnosis CX1100-0002 to K-Bus

0x1FA [2]

2 Byte PLC Interface CX1100-0002 to K-Bus

0x1FC [4]

reserved

Legacy PLC interface (outputs)

Offset

default

0x3F8 [2]

diagnosis K-Bus to CX1100-0002

0x3FA [2]

2 Byte PLC Interface K-Bus to CX1100-0002

0x3FC [4]