43a 3b 2 – American Time H004228 Master Clock Synchronizer User Manual
Page 4
© American Time
3
Connecting the Master Clock Synchronizer Module
SiteSync IQ Master Clock
Synchronizer
MTM Menu
Transmit Duration:
2000
OK=Done
MTM Menu
Master to Master:
1=Tx
3=Off
2=Rx
MTM Menu
Sync Time:
12:00:00
<>AM/PM
OK=Done
MTM Menu
Enter User Lock:
____
PROG=Exit OK=Enter
4
3a
3b
2
Turn on the power to the System Controller
u
Set the SiteSync IQ System Controller to be a transmitter (Tx) of the
contact closure. Press
P9
to enter Master to Master (MTM)
Menu.
v
Enter User Lock. Press
O
.
w
a. Press
1
to set the SiteSync IQ System Controller to Tx.
b.
Enter transmit duration (0-9999). Press
O
.
Example: 2,000ms=2 seconds
n
Note: The SiteSync IQ System Controller will round up to the nearest
second.
x
Using the keypad, set the time when the contact closure should
occur. Us
e
<>
to select AM or PM. Press
O
.
n
Note: Reference existing equipment instruction manual for contact
closure time.
n
Important Note! The Sync Time set in Step 4 must be the same
for both units.