Jumper J3
The J3 jumper connection controls Port A emulation mode and communi-
cation with the 7 x 5 LED. When the shunt is placed, Port A emulation is
disabled. See Table 14.

Jumper J7
The J7 jumper connection controls Flash boot loader programming. When
the shunt is placed, overwriting of the Flash boot loader program is
enabled. See Table 15.

Table 14. J3—DIS_EM

Shunt
Status

Function

Affected Device

In

Application Module
Hardware Disabled

Communication with 7 x 5 LED and Port emulation
circuit is disabled.

Out

Application Module
Hardware Enabled

Communication with 7 x 5 LED and Port A emulation
circuit is enabled.

Table 15. J7—FlashWE (Off-Chip)*

Shunt
Status

Function

Affected Device

Out

The Flash boot sector of the eZ80F92
Flash Module is write-protected.

Flash boot sector of the eZ80F92 Flash
Module.

In

The Flash boot sector of the eZ80F92
Flash Module is enabled for writing or
overwriting.

Flash boot sector of the eZ80F92 Flash
Module.

Note: As shipped from the factory, external Flash memory is not installed.