Installation procedures – Pinnacle Systems SS User Manual
Page 19

- A - 11 -
Installation Procedures
Model SS Safety Light Curtain
Wiring
Emitter Pylon
Terminal#
Connector
Defi nition
1
Black
Ground
2
Red
+24vdc regulated input
3
White
CAN_L data network
4
Green
CAN_H data network
Each pylon comes standard with 21’ (6400mm) of cable
with a quick disconnect in-line connector
Optional longer cables can be purchased (to replace the
20’ (6096mm) section). Voltages applied are to never
exceed 24vdc.
Terminal#
Defi nition
1
+24vdc regulated input
2
Ground
3
CAN_H data network
4
CAN_L data network
Optional RSD
WARNING: You must wire both Outputs 1 & 2 to a
“Safety Relay Module Control Reliable” Safety PLC,
when this product is used for safety guarding.
Wire all the Grounds together to the power supply.
Wire all the 24vdc together to the power supply.
Wire all the CAN_H together
Wire all the CAN_L together
Wire Output 1 and Output 2 to the “Safety Relay Module”
(see manufactures installed instructions)
Table 2a: Emitter Pylon Wiring
Table 2b: Receiver Wire Colors
Table 2c: Optional RSD
IMPORTANT: OUTPUTS 1 & 2 MUST BE USED
WITH EITHER “CONTROL RELIABLE” PLC INPUT
CIRCUITS OR A SAFETY RELAY MODULE.
Multiple Pylon Model SS Guard System
Multiple SS Guards scanning sequentially to
prevent interference with each other.
-MP Blocking one unit will not affect the others
connected together. You must have Safety Relays
for each SS Guard. If the separate SS guards are
NOT connected together via the CAN data network,
they scan independently and act as standard SS
guards.
-MP# Blocking one unit will shut off the outputs of
ALL units connected together. This allows 3 SS
guards to interface with 1 set of Safety Relays. If
the separate SS units are NOT connected together
via the CAN data network, ALL SS units will fault out
as a safety measure. # is the number of SS guards.
(See wiring diagram A-13 28-149)
All RED wires connect together and then connect to
+24vdc power supply
All BLACK wires connect together and then connect
to
GROUND
All ORANGE wires connect together and then
throughthe N.C. contacts of both Safety Relays
to GROUND
All PINK wires connect together
All WHITE wires connect together
Connect the GREEN wires together from Emitter
and Receiver of 1 SS Guard. (The GREEN wires
between guards are NOT connected together.)
Receiver Wire Colors
Terminal#
Connector
Defi nition
1
Red
+24vdc regulated input
2
Black
Ground
3
White
CAN_L data network
4
Green
CAN_H data network
5
Blue
Output 1 (24 vdc when
Green) (open when red)
(.25A
max)
6
Brown
Output 2 (24vdc when
Green) (open when Red)
(.24A
max)
7
Orange
EDM (GND when RED,
OPEN
when
GREEN)
8
Pink
Latching Relay Reset
(GND, then OPEN to
reset
Outputs)