beautypg.com

12 volt key-on power gr ound, Controlled device output, 5 volt output based on mph, .02 volts per mph – Lingenfelter L460050000 Lingenfelter STOV-002 MPH Activated Switch v3.5 User Manual

Page 9

background image

Page 8 of 12

0

1

3

5

6

7

2

4

8 9

A

B

C

D

E

F

0

1

3

5

6

7

2

4

8

9

A

B

C

D

E

F

Power

STOV-002

Speed to Voltage

Ground - Black

Stage Out / Norm On - Gray

Activation Out / Norm Off - Green

PPM Signal Input - White

Convertor

Function Selection

Range Selection

+12V Switched Power - Red

Voltage Out - Yellow

85

86

30

87a

87

+12 Volt

Key-On Power

Gr

ound

0-5

Volt output based on

MPH, .02

Volts per MPH

Normally ON Output, ON when

MPH is below set point. OFF

when MPH exceeds set point.

Normally OFF Output, OFF when

MPH is below set point. On when

MPH exceeds set point.

Connect to VSS (Pulse Per Mile)

signal from PCM

Relay will ONLY be ON

when MPH is below

set point.

Controlled Device Input

Signal Disable Installation, Function Switch Set to Position 1

(Example- Fan Relay Control)

Controlled

Device

Output