beautypg.com

Konig Electronic Wireless alarm system User Manual

Page 9

background image

ENGLISH

9

on the remote control to arm the alarm and OFF to disarm. The delay time

for entering and leaving the protected area is between 20~25 seconds.

7. It’s recommended to test the alarm system for correct operation with first

use and every 3 months.

Procedure:

a) Switch on the alarm unit to ALARM or CHIME (for testing recommend).

b) Push the ON button on the remote control to arm the alarm.

c) Wait for 20~25 seconds (delay time).

d) For testing door/window sensor, open every door or window one

by one and check if the corresponding LED lights up and the CHIME

sounds.

e) For testing PIR sensor, move around the PIR sensor and check if the

corresponding LED lights up and the CHIME sounds. Note: the LED

indicator on the PIR sensor lights up also.

f) Disarm the alarm if everything operates correct.

g) The alarm system is ready to use.

Note:

1) The alarm unit will give a conformation tone when armed or disarmed. The

tone for CHIME is different as for ALARM.

2) If a sensor does not need to be switched on, it’s possible to switch off every

sensor individually with the on/off switch. In this case the sensor is no part

of the alarm system anymore when armed (except PIR sensor).

3) A sensor switched to RF+ALARM will always give an alarm sound on the

sensor itself, unless the alarm unit is armed or disarmed.

4) When a sensor is triggered and the siren of the alarm unit sounds, it needs

to be switched off with on/off switch of the alarm unit. After that the alarm

unit can be switched on again. When the alarm keeps on going after arming

the system, check if every sensor is installed properly.

Specifications:

Alarm unit (figure 1):

• Power:

4.5 V DC (3x battery AA, not included)

• Standby current:

<1.5 mA

• Chime current:

<90 mA

• Alarm current:

<130 mA

• Alarm volume:

100 dB (0.5 m)