General installation recommendations installation – Hatteland Display HM C01 (Rugged) User Manual
Page 16
16
IND100210-4
General Installation Recommendations
Installation
Computer Upgrade Precaution Note
Users who needs to open the computer to change PCI cards, install more memory, or set internal jumpers can do so
without voiding the warranty. Before opening a unit’s housing to remove or touch a board, proper ESD measurements
must be taken!
1. Operator should ground himself by using a wrist band.
2. The wrist band should be connected to ground via a ground cord.
3. A one megaohm resistor, installed in the wrist connection end of the ground cord, is a safety requirement.
4. Alternatively an Static-dissipative ESD work mat could be positioned at the workplace.
The 3M™ 8501 Portable Field Service Kit is a good choice for this purpose.
All assisting persons who might come into contact with the endangered boards must also use the ESD equipment.
CAUTION
This unit contains electrostatic sensitive devices.
Observe precautions for handling.