beautypg.com

Appendix c: technical specifications – American Energy Systems Crossfire Pellet User Manual

Page 48

background image

Version

4.0

48

APPENDIX C: TECHNICAL SPECIFICATIONS

Fuel Type:

Hardwood

Pellet Fuel

A.P.F.I.

residential

fuel

Heat

Content:

8200

BTU/lb

Ash

Content:

1%

max

5.9 lbs/hour maximum feed rate

Bulk Density: 40 lb./cubic ft. min

Moisture

Content:

8%

max

Size: 1/4” to 3/8” diameter x 1.5” long max.

Fines: 1% max through 1/8

th

screen



Hopper Size:

55 pounds wood pellets


Flue Size:

4” recommended. If less than 10 feet use of 3 inch pipe is approved.


Flue Type:

PL double wall vent with stainless steel inner liner


Air Inlet:

3 inch by .15 inch walled steel pipe


Auger Type:

1

7/8”

cup Auger Feed System


Controls:

Country

Flame

Intelli-Choice Control Board


Electrical:

120 Volts, 2.4 Amp, 60 Hz


Measurements:

CROSSFIRE HEIGHT (at front)

22.5”

CROSSFIRE

DEPTH

(from

shroud) 14.0”

CROSSFIRE

WIDTH

(rear)

26.0”

CROSSFIRE

WIDTH

(at

shroud

mount)

25.5”


Weight :

STOVE

WEIGHT 220

POUNDS


Clearances:

UNIT

TO

SIDEWALL

7”

UNIT TO SIDE TRIM

7”

UNIT TOP TO SIDE TRIM

9.25”

UNIT TOP TO MANTLE

9.25”

HEARTH

FLOOR

TO

MANTLE

32”

NONCOMBUSTIBLE FLOOR PROTECTION (front)

6”

NONCOMBUSTIBLE FLOOR PROTECTION (sides)

6”


Shroud Measurements:

SHROUD WIDTH (standard)

42.0”

SHROUD HEIGHT (standard)

30.0”

SHROUD WIDTH (oversized)

48.0”

SHROUD HEIGHT (oversized)

32.5“

*BTU/lb can vary depending on the moisture content of the pellet.