beautypg.com

StarTech.com STHDBTRX User Manual

Page 23

background image

Instruction Manual

20

Output to Input

Return status

OP3->IP3

“s32”

OP3->IP4

“s33”

OP4->IP1

“s40”

OP4->IP2

“s41”

OP4->IP3

“s42”

OP4->IP4

“s43”

Read Status Command

The command length is 4 bytes.
bc + ‘_’ + ‘ ’
“bc” is the key word, ‘_’ is Space, ‘ ’ is carriage return.
When you send the read status command to MX0404, if succeed, it will return the

status of the OP(both OP1 and OP2).
Example: when you send the above command to the ST424HDBT it will

feedback”s1xs2ys3zs4a”, which means OP1 selects IP(x+1) , OP2 selects IP(y+1), OP3

selects IP(z+1) ,OP4 selects IP(a+1). ”s12s23s33s40” means OP1 selects IP3, OP2 selects

IP4, OP3 selects IP4 and OP4 selects IP1.

Web Password Reset

The command length is 4 bytes.

rpw+ ‘

“rpw” is the key word , ‘ ’ is carriage return.
When you send the Web password reset command to ST424HDBT it will feedback

"rpw" and the web password will be set as "0000000000".