Motor modes, Chapter 5 motor modes – B&C Technologies EL-6 Windows User Manual
Page 33

Chapter 5
Motor Modes
Motor Modes are used to set the agitation profile for each step. There are 5 stock motor modes
used:
• Mode 1 – Standard wash agitation: 16 seconds forward, 4 seconds pause, 16 seconds reverse
• Mode 2 – Gentle wash agitation: 4 seconds forward, 16 seconds pause, 4 seconds reverse
• Mode 3 – Soak agitation: 5 seconds forward, 115 seconds pause, 5 seconds reverse
• Mode 14 – Reverse only: Used in the rebalancing function after an unbalance condition.
• Mode 15 – Forward only: Used in extract cycles
Figure 5.1: Motor Mode Area
To customize or add a new motor mode, simply double click in the field you wish to adjust. Refer
to figure 5.1 on page 30. When the sub-menu appears, change the seconds value to fit the process.
Any value between 1 and 240 seconds may be entered.
30