PulseTech HD-BT12 Bench Top Charger (746X850) User Manual
Page 9

- 7 -
c) Connect the charger in accordance with paragraphs 1-16.
d) Turn on switch located adjacent to the IEC input connection. This
switch has a built in circuit breaker. If the charger turns off for no
apparent reason, turn the switch to the off position and turn it back
on again. DO NOT TAMPER WITH OR REMOVE SWITCH.
e) See paragraph 19 for explanation of the LED indicators.
19. INDICATORS:
a)
The unit will conduct a self-test when the power is turned on. Each
Channel will illuminate all five of its LEDs to confirm that it is
operating properly.
b)
Battery Disconnected – The charger does not sense a battery
present; connect the clamps to a battery to be charged.
c)
Bad Battery – The battery is not recoverable; remove and properly
dispose of the battery.
d)
Recovery Charge – The battery is in a deeply discharged state and is
being recovered to allow for Pulse Charging; no action is required.
e)
Pulse Charge – The battery is being charged; no action is required.