PulseTech HD-BT12 Bench Top Charger (746X850) User Manual
Page 8

- 6 -
b) Attach at least a 24-inch-long 6-gauge (AWG) insulated battery
cable to NEGATIVE (NEG, N, -) battery post.
c) Connect POSITIVE (RED) charger clip to POSITIVE (POS, P, +)
post of battery.
d) Position yourself and free end of cable as far away from battery
as possible – then connect NEGATIVE (BLACK) charger clip to free
end of cable.
e) Do not face battery when making final connection.
f) When disconnecting charger, always do so in reverse sequence of
connecting procedure and break first connection while as far away
from battery as practical.
g) A marine (boat) battery must be removed and charged on shore.
To charge it on board requires equipment specially designed for
marine use.
17. ASSEMBLY INSTRUCTIONS:
a)
Unit is supplied with 12 battery cables. Each battery cable is
interchangeable with the panel mounted connectors located at the
front of the charger.
18. OPERATING INSTRUCTIONS:
a) The charger must be assembled in accordance with paragraph 17
prior to use.
b) This charger is designed to accept input of 100-250VAC, 15/7.5A,
50/60Hz. It is provided with a 120V North American IEC input cord.
If using voltage other than 120V, use a properly rated, UL approved
IEC input cord. The charger is for conditioning and charging 12V
batteries only with an output power of 14.8Vdc, 6A max. This
charger is designed to operate 0°C - 50°C and 10% - 85% humidity.
Charger is for indoor/outdoor use.