Operation, Caution, Warning – BE Pressure supply 2500 Watt Inverters Generators User Manual
Page 20: Notice
20
operation
CAUTION
When the output indicator light (green) does not light and the overload
indicator light (red) lights instead, set the engine switch to STOP, stop
the engine at once and then start the engine again.
WARNINg
Check that the equipment to be connected is switch
off. When the equipment to be used is switched on, it
will operate suddenly, and injuries or accidents may be
caused.
2. Start engine according to “STARTING THE ENGINE”
3. Confirm that the equipment to be used is switched off, and insert the
plug of the equipment to be used into the AC receptacle unit A.
NOTICE
When equipment requires a large starting power, the overload indicator
lights (red) and the output indicator light (green) may light together for
a short time, but this is no abnormality. After start of the equipment, the
overload indicator light (red) will go out and the output indicator light
(green) will stay lit.
AC
Electric Lamps Power Tools
Electromotor
DC Battery
Power Factor
1
0.8-0.9
0.4-0.7
(efficiency 0.86)
I2500
0-2000W
0-1520W
0-760w
Rated voltage 12V
Rated current 6A (for Canada),
8A (except for Canada)
I3500
0-2600W
0-2000W
0-10002
When Overloaded
or short circuited,
Overload Indicator
Light (Red) will
illuminate
Normal: Output
indicator will
illuminate
4. Switch on the equipment output indicator light will glow. In case of
overload operation or when trouble occurs for the equipment being
used, the output indicator light (green) will go out, the overload
indicator light (red) will light continuously, and no power will be put out.
At this time, the engine may not stall, flick the engine switch to STOP
to turn off.
**I2500 Image
I2500_3500 Inverter Generator Manual_2011.indd 20