Specifications – Wood’s Powr-Grip PT10FS10TDC User Manual
Page 3
Rev 10.0/4-13
1
PT10HV11FDC: #35144
SPECIFICATIONS
Model Number:
PT10HV11FDC(O) or PT14HV11FDCO
Description:
Designed for use with a crane or other hoisting equipment, all variations of the
PT10HV11FDC lifter employ vacuum to hold a load for lifting, and they provide powered 90°
tilt movement for load manipulation.
Power Source:
12 volts DC, 54 amps
Battery Capacity:
35 amp-hours
Vacuum Pads:
10" [25 cm] nominal diameter, lipped (Model HV11), standard rubber, spring-mounted (¼"
[7 mm] travel), with #60 filter screen and closed-cell foam rings for applications on rough or
textured surfaces.
Pad Shutoffs:
Manual valves control vacuum flow at adjacent pads.
Pad Spread: (to outer edges)
(w/10 pads - standard)
(w/10 pads - optional)
(w/14 pads - optional)
Minimum:
11" x 32" [279 x 813 mm]
11" x 32" [279 x 813 mm]
11" x 30¾" [279 x 781 mm]
Maximum:
23" x 74" [584 x 1880 mm]
33" x 74" [838 x 1880 mm] 60" x 90" [1524 x 2286 mm]
Lifter Weight:
400 lbs [182 kg]
420 lbs [191 kg]
585 lbs [266 kg]
Load Capacity:
(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
1
)
Per-Pad:
150 lbs [68 kg]
Note: Calculated lifting capacities cannot
Maximum:
1500 lbs [680 kg]
exceed Maximum Load Capacity.
Tilt Capability:
Powered, 90°; Speed = approx. 21 seconds; Duty = 36 tilts per hour (under maximum load;
tilt duty increases as load weight decreases)
Vacuum Pumps:
2 diaphragm type, 1 SCFM [28 liters/minute] nominal airflow
or
1 diaphragm type, 3 SCFM [85 liters/minute] nominal airflow
Vacuum Reserve Tank:
Vacuum reservoir helps prevent immediate vacuum loss in case of power failure and extends
battery life by reducing pump cycles required to maintain vacuum.
Vacuum Gauge:
Dial gauge indicates current vacuum level in positive inches of Hg and negative kPa.
Vacuum Lift Light:
Green light is energized whenever vacuum level is sufficient for lifting maximum load weight
(higher than 16" Hg [-54 kPa]).
Options:
Available
with Model CF9ADO - Alternative Dimension Pad Frames. These options enable a
lifter to handle loads with different dimensions from those of the standard pad frame.
Available
with Model LB9HEO - Control Handle Extensions. This option moves the control
handle 36" [91 cm] outward from the standard position, enabling the operator to maintain
control of the lifter while remaining outside the path of tilting loads.
See separate instructions about other optional features.
Operating Elevation:
Maximum = 7000 feet [2133 meters]
Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:
This lifter is designed to have a service life of at least 20,000 lifting cycles, when used and
maintained as intended. Vacuum pads, filter elements and other wear-out items are
excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more information. For the
D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.powrgrip.com for more information)
Wiring Diagram:
The following wiring diagrams are attached for reference in servicing the lifter or trouble-
shooting a deficiency:
!!-CE-!! Note: This symbol appears in the
INSTRUCTIONS
manual only when requirements of a CE Standard are
different
from requirements of
other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas where CE Standards apply, but may
be optional in other locations.
1
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.