Connect ductwork – Broan 61000 User Manual
Page 7
- 7 -
6" ROUND
METAL DUCT
DECORATIVE
FLUE
DUCT TAPE
AIR VENT
POSITION FOR
DUCTED
CONFIGURATION
CONNECT DUCTWORK
Ducted Configuration
1. Use (2) screws (4.8x38mm) and wall
anchors to secure upper bracket to the
ceiling or wall as shown.
2. Use 6" round metal duct to connect the duct
collar on the hood to the ductwork above.
3. Use duct tape to make all joints secure and
air tight.
4. Remove the 2 screws securing the flues.
5. Connect the upper section of decorative flue
to the bracket with screws provided
(3.2x13mm).
6. Slide the lower section of decorative flue
downward, until it fits properly around hood.
7. Secure decorative flue to hood with screws
provided (3.2x13mm).
FASTEN
FLUE TO
HOOD & UPPER
BRACKET WITH
SCREWS
(3.2x13mm)
FLUE MOUNTING
BRACKET
MOUNTING
SCREWS
(4,8x38mm)
FIXING TO THE WALL
FIXING TO THE CEILING
FLUE MOUNTING
BRACKET
MOUNTING
SCREWS
(4,8x38mm)