Install the hood, Wiring – Broan 61000 User Manual
Page 6
- 6 -
DEPTH ADJUSTMENT
SCREWS
WALL FRAMING
MOUNTING
SCREWS
(4.8x38mm)
RECTANGULAR CUTOUTS
MOUNTING
BRACKETS
HEIGHT
ADJUSTMENT
SCREWS
MOUNTING
SCREWS
(4.8x38mm)
INSTALL THE HOOD
3. Remove the tape located on the damper.
4. Hang the hood from the brackets through
the rectangular cut-outs on the back of the
hood. Cut-outs are larger than the brackets
to allow for horizontal adjustment.
The bottom of the hood should be 24" to 30"
above the cooking surface.
5. Height adjustment screws provide vertical
adjustment.
6. Depth adjustment screws provide
horizontal adjustment.
7. Secure the hood with mounting screws
(4.8x38mm). Use drywall anchors, provided,
if wall studs or framing are not available.
REMOVE THE TAPE
WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Secure the conduit to the wiring box
through a conduit connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.
DUCT
COLLAR
WIRING BOX
COVER