beautypg.com

Bosch 2400EO User Manual

Page 13

background image

13

Troubleshooting

6 720 606 990

B Double check all wire connections

made under section 4.2 of the
remote control manual. Pay close
attention to the wire connecting the
remote's PCB to the heater's main
PCB.

3. Remote display shows "- -" only

B Verify the water heater's ON/OFF

switch is turned to the ON (I)
position. If the water heater's display
is still blank, verify the heater is
plugged into a live 120VAC/ 60Htz
properly grounded outlet.

B Verify there is proper voltage to the

water heater (120VAC/60Htz).

B Verify the remote is within the

maximum distance from the water
heater of 98 feet.

B Ensure that no other device in the

area, such as a cordless phone, is
operating on a frequency similar to
the remote (915 MHz) and causing
interference

4. Error code and “

” symbol

will not clear from remote

B

Error codes cannot be reset by

using the remote. All errors must be

cleared by using the reset button

on the water heater's main

control panel

• If an error code is generated immedi-

ately after the installation of the
remote control transceiver PCB,
ensure two large electrical connec-
tors (Fig. 4) on the main PCB are
properly seated.

• Error code may not be resettable.

Consult water heater's installation
manual or www.boschhotwater for
further troubleshooting on error
codes.

i

Large amounts of metal
or concrete in the
structure may have a
blocking effect on the
remote's signal. This
may alter the maximum
distance allowable from
the water heater.

B Move within direct

line of sight of the
water heater to see if
signal will reconnect.

6720606990-0701_(Remote control).fm Page 13 Tuesday, January 30, 2007 10:07 AM